C-10 Electrician for Permit Correction

via Freelancer ·

Budget / Salary$250–750
TypeFreelance project
LocationRemote
Posted4 hours ago
California C-10 Electrician Needed – Generac Generator Permit Correction

Location: Lakehead, California (Shasta County)

I am looking for an experienced California-licensed C-10 electrical contractor to complete a relatively limited correction to an existing residential Generac whole-home standby generator installation.

This is NOT a new generator installation. The generator system is fully installed, operational and already in use.

The existing installation includes:

Generac whole-home standby generator installed on concrete pad

Gas supply to generator already installed

Existing Generac 200A automatic transfer switch (ATS), installed and operational

Generator power and control wiring already installed

Associated conduit already installed

Existing house electrical circuits and breakers

Generator and ATS are currently functioning properly

The Issue

The installation did not pass Shasta County inspection because the existing listed meter/main/breaker panel had been physically modified as part of the connection to the ATS.

We have subsequently discussed the issue in detail with the Shasta County Building Division. The primary correction is expected to involve replacing/correcting the existing meter/main/breaker equipment and establishing an approved connection between the utility service, existing Generac 200A ATS and house distribution system.

We want to retain the existing generator and ATS and reuse existing compliant wiring, conduit, breakers and other equipment wherever practical.

Scope

We are looking for one contractor who can take responsibility for the correction from design through final approval, including:

Review the existing drawings and County correspondence.

Determine the simplest and most economical code-compliant correction.

Identify the required replacement service/distribution equipment.

Prepare/revise the electrical one-line drawing for Shasta County.

Submit/support reasonable revisions required during County plan review.

After approval, complete the corrective electrical work on site.

Coordinate PG&E disconnect/reconnect or meter work if required.

Reconnect existing circuits and the existing ATS as required.

Test the completed generator/ATS system.

Support the project through final Shasta County inspection/approval.

The objective is not to redesign or replace an otherwise functioning generator system. We want the least complicated compliant correction to the service/panel portion of the installation.

Detailed Project Package Available for Interested Parties able to travel to Lakehead, CA

I have prepared a detailed project package for qualified interested bidders. It includes:

Existing approved permit drawings and electrical one-line

County permit and inspection documents

Written correspondence with the Shasta County Building Division confirming our understanding of the required correction

Generac generator and ATS information

Existing conductor/conduit information

Detailed photographs of the meter/main panel, ATS and modified panel connections

The package will be provided to qualified interested bidders upon request. Additional photographs and measurements can also be provided.

Contractor Requirements

On-site work in Lakehead, California is required. Remote drawing-only proposals will not be considered.

Please include with your bid:

California C-10 contractor license number

Your location

Relevant Generac/standby generator experience

Experience with 200A residential service/panel work

Experience working with PG&E

Confirmation that you can perform the on-site work in Lakehead

Proposed approach and pricing

Experience with Shasta County permitting is a plus.

Pricing

Please provide pricing in two phases if practical:

Phase 1: Site visit (if required), design, equipment selection, revised one-line and County plan-review support.

Phase 2: Replacement equipment, on-site corrective work, PG&E coordination if required, testing and final inspection support.

We prefer to have the proposed correction reviewed/accepted by Shasta County before purchasing significant equipment or beginning corrective work.

Our priorities are simple: retain the existing generator and ATS, reuse compliant existing equipment wherever practical, keep the correction economical, and obtain final County approval.
project management electrical engineering construction management
Apply on Freelancer →

Project sourced from Freelancer.com. Applications happen directly on the original platform — we never collect your data.